Mô tả sản phẩm: Digital Power Meters Yokogawa WT300 Series
The WT300 Series Digital Power Meters are the 5th generation of Yokogawa’s highly recognized high performance low cost product group. They offer updated and innovative measurement functions which will benefit the engineer with basic electrical power measurements. They are the ideal measurement solution for doing Stand-by-Power measurements, Energy Star®, and IEC62301 testing, Battery Charger and other low level power measurements.
Applications
Name | Description | |
---|---|---|
Precision Bearing Vibration Test (WT333/SL1000/MX100) | The precision beaning testing system of the mechanical and electrical engineering company. | Learn More |
Lighting Test by WT310 & MX100 (for WT310/MX100) | Lighting products need to evaluate not only power parameters but also temperature. | Learn More |
Cleaner Test (for WT310) | Evaluation of vacuum cleaner requires to measure distorted waveform. | Learn More |
Washing machine Evaluation using D/A output (for WT310) | In the test of new washing machine, voltage, current, power, and the control signal on the time control panel need to be recorded. | Learn More |
Performance Evaluation and Testing of Home Electronics (for WT310) | Prevention of global warming has become an issue in recent year, and industry is turning more and more toward stricter energy savings policies and the use of renewable energy. | Learn More |
Evaluation of IH Cooking heater (for WT310HC) | In recent years the buzzword “all electric” is becoming popular, which refers to kitchen appliances, water heaters, and other devices in the home all being supplied with electric power. | Learn More |
Current Distortion (THD) test for Production line (for WT310) | Conventionally, measurement of the harmonic distortion required special modes or lengthy data acquisition times which impacted the processing time on manufacturing lines. | Learn More |
Features
The WT300 series digital power meters offer users the high performance and reliability customers have come to trust from Yokogawa.
The WT300's enhanced specifications and its wide range of functions let you handle all your measurement applications from low-frequency to high-frequency inverters using a single power meter.
First in Class:
Auto ranging function available in selected ranges.
The auto-range function is used to select or change the range automatically in specific ranges. This results in shorter range changing times, allowing more quick and efficient testing.
First in Industry:
Integration measurement auto ranging function.
Typically, when power meters operate in an integration mode to measure power consumption and standby power, the measuring ranges need to be fixed. However, if the level of the input exceeds the maximum of the selected range, the test will need to be repeated. The WT300 Series has a high speed automatic ranging capability in integration mode, which removes the need to repeat any test.
Comparison of WT210/230 with WT310/330
WT310/WT332/WT333 | WT310HC | WT210/WT230 | ||
DC power measurement accuracy | 0.1% of reading+0.2% of range | 0.3% of reading+0.2% of range | 0.3% of reading+0.2% of range | |
Current range (Crest factor=3)Voltage and current basic accuracy |
Direct Input | 5m/10m/20m/50m/100m/200m/ 0.5/1/2/5 /10/20[A]( WT310) 0.5/1/2/5/10/20[A](WT332/WT333 |
1/2/5/10/20/40[A] | 5m/10m/20m/50m/100m/200m/ |
External current input | EX1: 2.5/5/10[V] EX2: 50m/100m/200m/500m /1/2[V] (OP.) |
EX1: 2.5/5/10[V] EX2: 50m/100m/200m/500m /1/2[V] (OP.) |
EX1: 2.5/5/10[V] EX2: 50m/100m/200m[V] (OP.) |
|
Effective input range for voltage & current (CF=3) | 1% to 130% | 1% to 100% (40A range only) | 1% to 130% | |
Maximum displaying value for voltage & current (CF=3) | 1% to 140% | 1% to 110% (40A range only) | 1% to 140% | |
Effect of Power Factor (CF=3) | 0<PF<1 | Power reading x {power reading error + (power range / apparent power reading) + tanφ x (influence when PF = 0)} % | Power reading x {power reading error + (power range / apparent power reading) + tanφ x (influence when PF = 0)} % | Add the power reading x {tanφ x (influence when PF = 0)}%. |
Simultaneous measurement of RMS, Voltage MEAN & DC | Yes | Yes | No | |
Frequency measurement |
2 channels (voltage & current) |
2 channels (voltage & current) | selected voltage or current (one) | |
Number of display items | 4 items | 4 items | 3 items | |
Sampling rate | Approximately 100 kS/s | Approximately 100 kS/s | Approximately 50 kS/s | |
Harmonic measurement | Yes (OP, /G5) | Yes (OP, /G5) | Yes (OP, /HRM) | |
THD calculation maximum order setting | Yes (OP, 1-50th) | Yes (OP, 1-50th) | No | |
Auto ranging of integration | Yes | Yes | No | |
Communication interface | USB | Yes | Yes | NO |
GP-IB | Yes GP-IB or RS-232 | Yes GP-IB or RS-232 | Yes (OP) GP-IB or RS-232C | |
RS-232 | Yes RS-232 or GP-IB | Yes RS-232 or GP-IB | Yes RS-232 or GP-IB | |
Ethernet | Yes (OP) | Yes (OP) | NO | |
IEEE standard for GP-IB | IEEE488.2 | IEEE488.2 | IEEE488.1 and IEEE4882. | |
Comparator function | No | No | Yes | |
Viewer software | Free (included) | Free (included) | Free (download) |